TYPICAL SOLUTIONS FOR C&I PV STORAGE & CHARGING
2.3
EQUIPMENT SELECTION
Solar Module 2.3.1
MECHANICAL SPECIFICATIONS
Outer dimensions (L x W x H)
2094 x 1038 x 35 mm
Aluminum, silver anodized 3.2 mm Portrait: 300 mm Landscape: 1300 mm 4 mm² / 12 AWG 5400 Pa (front) / 2400 Pa (back) Class C (IEC) or Type 4 (UL) HCB40 / MC4-EVO2
Frame technology Front glass thickness Cable length (IEC/UL) Cable length (IEC/UL) ① Maximum mechanical test load
Fire performance (IEC/UL) Connector type (IEC/UL)
Refer to Astronergy crystalline installation manual or contact technical department. Maximum Mechanical Test Load=1.5×Maximum Mechanical Design Load.
MODULE DIMENSION DETAILS PACKING SPECIFICATIONS
① Module Weight
23.5 kg
② Packing unit Weight of packing unit (for 40‘HQ container) Number of modules per 40‘HQ container
31 pcs / box
772 kg 682 pcs
② Subject to sales contract
① Tolerance
+/- 1.0kg
MODULE DIMENSION DETAILS
A-A 40:1
1038 mm
35 mm
10:1
Grounding hole
11 mm
8-9 mm x 14 mm Mounting hole
20 mm 9 mm
989mm
Mounting hole 4-7 mm x 10 mm
989mm
16-3.5 mm x 8.5 mm Drainage hole
35 mm
© Chint Solar (Zhejiang) Co., Ltd. Reserves the right of final interpretation. please contact our company to use the latest version for contract.
19 CHINT
Powered by FlippingBook