This brochure contains brief information on CHINT's low voltage products such as Modular DIN Rail Product, MCCB, ACB, Contactors, Relays, Starters, Pushbuttons & Indictator Lights & Buzzers and Inverter & Soft-Starter.
Low Voltage Brief Catalogue
ABOUT CHINT
CHINT A leading global provider of smart energy solutions
Founded in 1984, CHINT is a leading global provider of smart energy solutions. It is actively deploying“4+1” industrial sectors including smart electrics, green energy, industrial control and automation, smart home and incubator, forming an integrated whole industry chain of “power generation, storage, transmission, substation, distribution, sales and consumption”. And it boasts an extensive business network across over 140 countries and regions as well as more than 30,000 employees and an annual sales revenue of over USD 11.4 billion. CHINT has been ranking among China’s Top 500 companies for 18 consecutive years. Its subsidiary, CHINT Electrics is the first company in China with low-voltage electrics as its main business getting listed on the A-share market as one of the Top 50 Asian listed companies. To comply with the trend of integrated development of modern energy, intelligent manufacturing and digital technology, CHINT has adopted “One Cloud & Two Nets” as the business strate- gy. CHINT Cloud fulfills digital application and services in both
internal and external as the platform of intelligent technology and data application. Based on the Industrial Internet of Things (IIoT), CHINT built an intelligent manufacturing system and realizes intelligent application in electrical industry. Relying on the Energy Internet of Things (EIoT), CHINT built its smart energy system and develops the regional EIoT mode. Focusing on energy system of supply, storage, transmission, distribution and consumption, CHINT has core businesses of clean energy, energy distribution, big data and energy value-added services. Furthermore, CHINT pillar businesses include photovoltaic equipment, energy storage, power transmission & distribution, low-voltage apparatuses, intelli- gent terminals, software development and control automation. With developing into a platform-based enterprise, CHINT provides a package of energy solutions for public institutions, industrial & commercial users and end users, by building a regional smart energy operation ecosphere.
ONE CLOUD & TWO NETS STRATEGY
Business Model Innovation
Solution Innovation
Optimization for Manufacturing and Supply Chain
Solutions and Services for Customers
Factory Operation and Maintenance Service System
Power Automation Solution
Product Design and Service System
Intelligent Manufacturing Solution
Intelligent Energy Storage System
Intelligent Building Solution
Industrial Automation Solution
Intelligent Photovoltaic System Solution
Distributed Microgrid Solution
Campus Energy Efficiency Solution
Process Automation Solution
Smart Water Solution
Chint Energy Internet of Things (EIoT)
Chint Industrial Internet of Things (IIoT)
Chint Industrial Internet PaaS Platform
Energy system optimization is an inevitable trend against the background of resource shortage, environmental pollution and climate change – three challenges faced by global energy devel- opment. To keep in line with the trend, CHINT actively imple- ments the business strategy of One Cloud & Two Nets, continu- ously promotes the deep integration of big data, IoT, AI and manufacturing industry in stages to become a platform-based enterprise, and leads the new direction of industry develop- ment. As a medium of smart technology and data applications, CHINT Cloud connects corporate in-house manufacturing with opera- tion and management data, realizing digital applications and services both internally and externally.
As a user-centric multi-energy complementary smart energy system, CHINT EIoT provides a package of energy solutions for governments, industrial & commercial users and end users. Its business includes Smart Energy Efficiency, Smart Power, Smart Home and Smart Clean Energy, etc. As a smart manufacturing system based on corporate digital transformation, CHINT IIoT constitutes a flexible, high-efficiency and intelligent industrial system. Its business includes Intelligent Manufacturing, Intelligent Industry, Smart Water, Smart Heating, etc.
GLOBAL FOOTPRINT
Moscow
Russia
Germany
Prague
Venice
Spain
North America
Frankfurt
Madrid
Europe
US
Los Angeles
Jiuquan
Xianyang
Egypt
Algeria
Shanghai
Hangzhou
Dubai
Western Asia and Africa
Wenzhou
Mexico
Asia Pacific
Thailand
Vietnam
Malaysia
Singapore
Global R&D Center
Latin America
International Marketing Territory
Peru
Brazil
Manufacturing Base
Sao Paulo
Logistics Center
GLOBAL CAPACITY LAYOUT The industrial manufacturing bases are mainly located in Wenzhou, Hangzhou, Shanghai, Jiaxing and Xianyang. Additionally, CHINIT has set up factories in Thailand, Egypt, Singapore, Vietnam, Malaysia, etc.
Egypt Production Base
Vietnam Production Base
Malaysia Production Base
Thailand Solar Power Production Base
Singapore Complete Electric Equipment Production Base
Shanghai Production Base
Hangzhou Production Base
Wenzhou Production Base
Jiaxing Production Base
Xianyang Production Base
R&D, QUALITY, SALES, LOGISTICS
By providing reliable products and service for clients, CHINT puts forward the concept "Great Quality." Quality control and upgrade is divided into four systems: scientific research, quality control, marketing service and logistics distribution. These methods and strategies make a comprehensive upgrade to product quality and services. Emphasis on "prevention first, continuous improvement" is the basis of an effective quality inspection system. Leading the management process of "Great Quality" in the production process controls each link of production accurately and realizes the institutional operation of quality improvement.
"Great Quality" is not just a slogan, but a belief rooted in each employee's work. High-quality and accuracy are the basic requirement. Starting from a routine operation by each staff to implementing a high-quality of production and service, CHINT is your most reliable partner.
Service Concept
Sincerely value care for customers, quality creates Service Purpose Innovative and progressive, satisfying the customers
48-Hour Response
Integrated Vertical R&D
Great Quality System One-stop Services
By gathering the global industry elites to Provide safe and stable energy-saving green and advanced electric products.
Providing end-to-end one-stop services for custom- ers with complains, business consulting and technical support by solving problems immediately and including any possible problems in advance.
CHINT's concept is that it is not difficult to fulfill a high-quality logistics distribu- tion at one time, while it is difficult to stay as accurat e and prompt as the first-time. High-efficiency and high-pre- cision accuracy are our requirement.
Ensuring flaw-fraw-free and trouble-free products, the multi-dimensional and multi- level control is conducted through procurement, inspec- tion, quality control and certification.
At least 5% of revenue is invested in research and development
Low Voltage Brief Catalogue
Modular DIN Rail Product
P-001
M CCB
P-0 45
A CB
P-0 55
Contactors, Relays, Starters
P-0 6 1
Pushbuttons & Indicator Lights & Buzzers
P-0 71
Inverter & Soft-Starter
P-0 77
Low Voltage
Brief Catalogue
Relay
P-0 83
LV Capacitor
P-10 3
Low Voltage VT & AVR & CT & PT
P-10 7
Switch Disconnector, Fuse-switch Disconnector, Changeover Switch
P-11 5
Fuses, Travel Switches,Universal Change-over Switches, Connection Terminals
P-1 21
Modular Din Rail Products Perfect Reliable C hoice
Modular DIN Rail Products
MCB
NB1-63G In: 1~63A
NB1-63H In: 1~63A 10000A
NB1-63 In: 1~63A Icn=6000A
In: 1~63A Icn=3000A, 4500A
Page P-002
Page P-003
Page P-001
Page P-001
NXB-40 In=6~40A Icu=4500A
NXB-63 In=1~63A Icn=6000A
NXB-63H In=1~63A Icn=10000A
NBH8 In: 1~40A Icn=4500A, 6000A
Page P-004
Page P-005
Page P-005
Page P-005
NB8-63H In=1~63A Icn=10000A
NXB-80 In=80A Icn=6000A
NXB-125G In=63A,80A, 100A,125A Icn=10000A
NB8-63 In=1~63A Icn=6000A
Page P-006
Page P-006
Page P-007
Page P-008
NB8-63M In=1~63A Icu=10000A
NB8-40J In=1~40A Icn=6000A
Page P-009
Page P-010
DC MCB
NB1-63DC In: 1~63A Icu=6000A
CB-125 In=63~125A Icn=20KA
CB-60 In=1~63A Icn=6KA
Page P-011
Page P-012
Page P-012
MCCB
DZ158 In: 63A, 80A, 100A, 125A Icu=6kA, 10kA
NXB-125 In=63~125A Icu=10000A
Page P-013
Page P-014
Modular DIN Rail Products
RCCB
NL210 B type In=25~63A
NXL-63 In=16~63A
NL1 A,AC,F type In=20~100A
Page P-015
Page P-016
Page P-017
RCBO
NB310L Magnetic type
NB2LE Electronic type
NB1L-40/63 Magnetic type
NB1L Magnetic type
Page P-018
Page P-019
Page P-020
Page P-021
NB3LEG-40 Electronic type
NB3LE Electronic type
NB3LEU Electronic type
NB4LE Electronic type
Page P-025
Page P-022
Page P-023
Page P-024
NBH8LE Electronic type
NB8LE-63M In=6~63A Icu=10000A
DZ158LE Electronic type
NXBLE-32 In=6~32A Icu=6000A
Page P-029
Page P-026
Page P-027
Page P-028
NXBLE-63Y In=6~63A Icu=4500A
NXBLE-125 In=60~125A Icu=7500A
NXBLE-63 In=6~63A Icu=6000A
NXBLE-40 I n=6~40A Icu=4500A
Page P-029
Page P-029
Page P-030
Page P-030
Accessories for MCB, RCBO
XF9 Auxiliary contact
XF9J Alarm auxiliary contact For NB1,NBHB, NB1L,NBH8LE
S9 Shunt release
V9 Under-voltage release For NB1,NBHB, NB1L,NBH8LE
For NB1,NBHB, NB1L,NBH8LE
For NB1,NBHB, NB1L,NBH8LE
Page P-031
Page P-031
Page P-031
Page P-031
Modular DIN Rail Products
AX-1 Auxiliary contact
AX-5 Auxiliary contact
OUVR-1 Self-recovery Protector
OUVR-2 Self-recovery Protector
For NL1
For DZ158, DZ158LE
Page P-032
Page P-032
Page P-032
Page P-032
AX-X1 Auxiliary contacts
AL-X1 Alarm auxiliary contacts For NXB, NXBLE series Page P-033
OUVT-1 Over/under voltage release
SHT-X1 Shunt release
Page P-033 For NXB, NXBLE series
Page P-033 For NXB, NXBLE series
For NB1 series
UVT-X1 Under-voltage release For NXB, NXBLE series Page P-033
OUVT-X1 Over/under voltage release For NXB, NXBLE series Page P-034
OVT-X1 Overvoltage release For NXB, NXBLE series Page P-033
AX-X3 Auxiliary contacts
Page P-034 For NXB-125, NXBLE-125
AL-X3 Alarm auxiliary contacts For NXB-125, NXBLE-125 series
UVT-X3 Under-voltage release
SHT-X3 Shunt release
OVT-X3 Over-voltage release
For NXB-125, NXBLE-125 series
For NXB-125, NXBLE-125 series
For NXB-125, NXBLE-125 series
Page P-034
Page P-034
Page P-034
Page P-035
OUVT-X3 Over/under voltage release For NXB-125, NXBLE-125 series
Page P-035
Switch Disconnector
NH2 In=32A, 63A, 100A, 125A
NH4 In=32A, 40A,63A, 80A,100A, 125A;
NXHB-125 In=20~125A
Page P-035
Page P-036
Page P-036
Modular DIN Rail Products
Change-over Switch
NZK1
NZK2
Page P-037
Page P-037
Surge Arrester
NU6-Ⅱ
NU6-Ⅲ
NU6-ⅡG
NXUI+II
Page P-038
Page P-038
Page P-039
Page P-040
Pushbutton & Indicator
NP9 Pushbutton
ND9 Indicator light
Page P-041
Page P-041
Consumer Unit
NX8
NX2
NXW1
Page P-042
Page P-042
Page P-042
Wall Mounting Enclosure
Busbar
NXW5
CBB-2 Busbar
Page P-043
Page P-044
Low Voltage Brief Catalogue MCB MCB
P-001 P 001 Low Voltage Brief Catalogue -
NB1-63(H) Miniature Circuit Breaker
1. General
▪ Short circuit protection ▪ Overload protection ▪ Switch ▪ Isolation ▪ Contact position indicator ▪ Advanced current-limit technology ▪ Heat dissipation gap for better cooling ▪ Extendable DIN-rail holder for easy installation
NB1-63
6kA
2. Technical features
IEC/EN 60898-1
IEC/EN 60947-2
Standard
UL1077
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
A
Rated current In
1P, 1P+N, 2P, 3P, 3P+N, 4P
1P, 2P, 3P, 4P
1P, 2P, 3P, 4P 1P, 2P
Poles
Rated voltage Ue
277/480
230/400~240/415
DC 110/125
V Hz A
Rated frequency
AC 50/60
Auxiliary contact Connection Mounting Mechanical life Electrical life Thermo-magnetic release characteristic Rated impulse withstand voltage (1.2/50) Uimp Energy limiting class Rated breaking capacity
6000/10000 3
6000
5000
10000
B, C, D 6000
V
(8-12)In
(4-7)In, (7-15)In
B, C, D
4,000 20,000 On DIN rail EN 60715 (35mm) by means of fast clip device From top and bottom
NB1-63H
10kA
Yes Yes Yes Yes
Shunt release Under voltage release Alarm contact
3. Curve
B, C, D curve
A A
DNV
014
Low Voltage Brief Catalogue MCB P-004 MCB 002 Low Voltage Brief Catalogue P -
BC B BG Miniature Circuit Breaker
1. General
▪ Short circuit protection ▪ Overload protection ▪ Switch ▪ Isolation ▪ Economic type breaker ▪ High cost - effective
eBC
2. Technical features
IEC / EN 60947-2
IEC / EN 60898-1
Standard
1, 2, 3, 4, 5, 6, 10, 15, 16, 20, 25, 32, 40, 50, 63
A
Rated current In Poles Rated voltage Ue Rated frequency
1P, 2P, 3P, 4P
230/400~240/415
V
50/60
Hz
3 (1A~63A) eBC 4.5 (1A~63A) eB 6 (B,C 1~40A) eBG
Rated breaking capacity
kA
Rated impulse withstand voltage(1.2/50)Uimp Thermo - magnetic release characteristic
4,000 B , C , D 4,000 10,000
V
(8-12) In
Electrical life
Mechanical life
Cable/Pin-type busbar
Terminal connection type
Mounting Connection
On DIN rail EN 60715(35mm) by means of fast clip device
From top and bottom
eB
3.Curve
B, C, D curve
eBG
Low Voltage Brief Catalogue MCB MCB
P-005 P 003 Low Voltage Brief Catalogue -
NB1-63G Miniature Circuit Breaker
1. General
▪ Short circuit protection ▪ Overload protection ▪ Switch ▪ Isolation ▪ Various wiring solutions: U-type/pin-type/Comb-type Busbar/Cable
2. Technical features
NB1-63G
IEC/EN 60898-1
Standard Rated current In Poles
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
A
1P, 2P, 3P, 4P 230/400 50/60
Rated voltage Ue Rated frequency Rated breaking capacity Rated impulse withstand voltage(1.2/50) Uimp Thermo-magnetic release characteristic Electrical life Mechanical life
V
Hz A
6000 4000 B, C 4,000 20,000
V
On DIN rail EN 60715 (35mm) by means of fast dip device From top and bottom
Mounting
Connection
3. Curve
B, C curve
t(s)
10000
2000 5000 1000
B
500
200 100
20 10 50
C
5
1 2
0.5
0.1 0.2
0.05 0.02 0.01
0.005
0.002 0.001
I/In 100 200
1
0.5
7 10
20
30 50 70
2 3 4 5
Low Voltage Brief Catalogue MCB P-006 MCB 004 Low Voltage Brief Catalogue P -
NBH8 Miniature Circuit Breaker
1. General
▪ Short circuit protection ▪ Overload protection ▪ Switch ▪ Isolation ▪ 1P+N in one module. ▪ Contact position indicator
NBH8
2. Technical features
On DIN rail EN 60715 (35mm) by means of fast clip device IEC/EN 60898-1 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40 1P+N 230~240 B, C 50/60 4500/6000 4000 8, 000 20, 000
Standard
A
Rated current In Poles Rated voltage Ue Thermo-magnetic release characteristic Rated frequency Rated breaking capacity Rated impulse withstand voltage(1.2/50) Uimp Electrical life Mechanical life
V
Hz V A
Mounting
Terminal connection type Auxiliary contact Shunt release Under voltage release Alarm contant
Cable/Pin-type busbar Yes Yes Yes Yes
3.Curve
B, C curve
t(s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2 1
0.5 0.2 0.1
0.05 0.02 0.01
0.005 0.002 0.001
0.5 1
2 34 5 7 10 20 30 5070100 200 I/In
Modular Din Rail Product ▪ Rated short-circuit breaking capacity: 6KA ▪ Short-circuit breaking capacity: 6KA ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation
P 005 Low Voltage Brief Catalogue -
NXB-40 Miniature Circuit Breaker
▪ Compliant standards: IEC60898-1 ▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A ▪ Rated voltage: 240 ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 4500A ▪ Short-circuit breaking capacity(Ics): 4500A ▪ Rated impulse withstand voltage(Uimp): 4kV
NXB-40
Modular Din Rail Product
P-081
Low Voltage Brief Catalogue
NXB-63 Miniature Circuit Breaker Modular Din Rail Product
P-081
Low Voltage Brief Catalogue
▪ Compliant standards: IEC60898-1 ▪ Rated current: 1A,2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 6000A ▪ Short-circuit breaking capacity (Ics): 6000A ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation ▪ Compliant standards: IEC60898-1 ▪ Rated current: 1A,2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 6000A NXB-63H Miniature Circuit Breaker ▪ Compliant standards: IEC60898-1 ▪ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity: 10000A ▪ Short-circuit breaking capacity: 7500A ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation ▪ Short-circuit breaking capacity (Ics): 6000A ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation NXB-63H Miniature Circuit Breaker ▪ Compliant standards: IEC60898-1 ▪ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity: 10000A ▪ Short-circuit breaking capacity: 7500A ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation NXB-80 Miniature Circuit Breaker ▪ Compliant standards: IEC60898-1 ▪ Rated current: 80A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Compliant standards: IEC60898-1 ▪ Rated current: 80A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P, 1P+N, 2P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity: 6KA ▪ Short-circuit breaking capacity: 6KA ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation NXB-63 Miniature Circuit Breaker NXB-80 Miniature Circuit Breaker
NXB-63
NXB-63
NXB-63H
NXB-63H
NXB-80
NXB-80
▪ Number of poles: 1P, 1P+N, 2P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity: 6KA ▪ Short-circuit breaking capacity: 6KA
NXB-40 Miniature Circuit Breaker
▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity: 10000A ▪ Short-circuit breaking capacity: 7500A ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation Modular Din Rail Product
NXB-63H
006 Low Voltage Brief Catalogue P -
NXB-80 Miniature Circuit Breaker
▪ Compliant standards: IEC60898-1 ▪ Rated current: 80A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D
NXB-80
▪ Number of poles: 1P, 1P+N, 2P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity: 6KA ▪ Short-circuit breaking capacity: 6KA ▪ Rated impulse withstand voltage (Uimp): 4kV ▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation
NXB-40 Miniature Circuit Breaker
NXB-125G
▪ Compliant standards: IEC60898-1 ▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A ▪ Rated voltage: 240 ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 4500A Compliant standards: IEC/EN60898-1 Rated current: 63A, 80A, 100A(1P, 2P, 3P, 4P), 125A(1P, 2P); Rated voltage: 230V ~ (1P), 400V~ (2P, 3P, 4P); Frequency: 50/60Hz Electromagnetic release type: B, C, D; ▪ Short-circuit breaking capacity(Ics): 4500A ▪ Rated impulse withstand voltage(Uimp): 4kV Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In ≤ 100A); 4000 cycles (In > 100A); Rated short-circuit breaking capacity(Icn): 10kA;
1. General
NXB-40
NXB-125G
Short-circuit breaking capacity(Ics): 7.5kA; Rated impulse withstand voltage(Uimp): 4kV;
MCB
P 007 Low Voltage Brief Catalogue -
NB8 -63
Miniature Circuit Breaker
2. TECHNICAL DATA
NB8-63
1. General
1.1 Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation. NB8 -63 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems. 1.2 Selection Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrush current. D curve(10-16In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Certificate CE
NB8-63
2.Technical features
3.Curve
t(S)
t(S)
t(S)
(S)
B curve (3~5In)
C curve (5~10In)
D curve (10~16In)
CHINT
02
MCB
008 Low Voltage Brief Catalogue P - Miniature Circuit Breaker NB8 -63H
2. TECHNICAL DATA
Standard
IEC 60947-2
NB8-63H
Rated current In Rated voltage Ue Rated frequency
A
1、2、3、4、6、10、16、20、25、32、40、50、63
V
230 / 400
Hz
50
1. General
Poles
1P, 1P+N, 2P, 3P, 3P+N, 4P
1.1 Function Protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation. NB8 -63H circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems. 1.2 Selection Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrush current. D curve(10-16In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Certificate CE A V B(3-5In),C(5-10In),D(10-16In), 20,000 10,000 10,000 500 KV 6
Thermo-magnetic release characteristic
Mechanical life
Electrical life Rated breaking capacity
Insulation voltage Ui
Rated impulse withstand voltage (1.2/50) Uimp
NB8-63H
2.Technical features
3.Curve
CHINT
02
MCB
P 009 Low Voltage Brief Catalogue -
NB8-63M
1. General
1.1 Function protection of circuits against short-circuit currents, switch, isolation. NB8 -63M circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems. 1.2 Selection Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage. Tripping curves: C curve (6.4In-9.6In) protection for resistive and inductive loads with low inrush current. D curve(9.6-14.4In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Certificate CE
NB8-63M
2.Technical features
3.Curve
MCB
010 Low Voltage Brief Catalogue P -
NB8-40J
1. General
1.1 Function Protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation. NB8 -40J circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems. 1.2 Selection Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrush current. D curve(10-16In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps) 1.3 Certificate CE
NB8-63H
NB8 -40J
Miniature Circuit Breaker
2. TECHNICAL DATA
2.Technical features
3.Curve
C curve(5~10In)
D curve(10~16In)
DC MCB
Low Voltage Brief Catalogue MCB P-002
P 011 Low Voltage Brief Catalogue -
NB1-63DC DC Circuit Breaker
1. General
▪ Excellent breaking capacity ▪ Double connection function of lead wire and bus bar ▪ Stored energy operation, fast closing, long service life ▪ Convenient installation, disassembly ▪ Contact on-off indication, higher security ▪ Green environmental protection and energy saving
NB1-63DC
2. Technical features
IEC/EN 60947-2
Standard
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
A
Rated current In Poles Rated voltage Ue Mechanical life Electrical life
1P, 2P, 4P
1P: 250V; 2P: 500V; 4P: 1000V
V
1,500 20,000
3.Curve
C curve
t(s) 10000 5000 1 H
2000 1000
500 200 100
50 20 10
5 2 1
0.5 0.2 0.1
0.05 0.02 0.01
0.005 0.002 0.001 0.5 1 2 3 45 7 10 20 30 5070100200
I/In
DC MCB
012 Low Voltage Brief Catalogue P -
CB-60 DC Circuit Breaker
1. General
Compliant standards: IEC/EN 60898-2, IEC/EN60898-1, EN60947-2 Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Rated voltage: DC60/110(1P),DC80/125/220(2P); Electromagnetic release type: B, C ; Number of poles: 1P, 2P; Mechanical life: 20000 cycles; Electrical life: 10000 cycles Rated short-circuit breaking capacity(Icn): 6kA;
CB-60
CB-125 DC Circuit Breaker
1. General
Compliant standards: EN60947-2; Rated current: 63A, 80A, 100A, 125A; Rated voltage: DC60/110(1P),DC80/125/220(2P); Number of poles: 1P, 2P; Mechanical life: 20000 cycles; Electrical life: 8000 cycles Rated short-circuit breaking capacity(IcU): 20kA;
CB-125
Low Voltage Brief Catalogue MCCB MCCB
P-007 P 013 Low Voltage Brief Catalogue -
DZ158 Moulded Case Circuit Breaker
1. General
▪ Short circuit protection ▪ Overload protection ▪ Switch ▪ Isolation ▪ Contact position indicator
2. Technical features
DZ158
IEC/EN 60947-2 63, 80, 100, 125 1P, 2P, 3P, 4P 230/400~240/415
Standard Rated current In Poles
A
Rated voltage Ue Rated frequency Rated breaking capacity Rated impulse withstand voltage(1.2/50) Uimp
V Hz
50 6/10
kA
V
4000
Thermo-magnetic release characteristic
(8-12)In
1,500 (In=63A, 80A, 100A) 1,000 (In=125A) 8,500 (In=63A, 80A, 100A) 7,000 (In=125A)
Electrical life
Mechanical life
On DIN rail EN 60715 (35mm) by means of fast clip device
Mounting
From top and bottom
Connection
3.Curve
t(s) 10000 8000 1h (or 2h)
2000 1000
500 200 100
50 30 20 10
5 2 1
0.5 0.2 0.1
0.05 0.02 0.01
0.005 0.002 0.001
0.5 11.3 2 45 8 12 3
20 30 50 70 100
I/In
MCCB
014 Low Voltage Brief Catalogue P -
NXB-125
1. General
Compliant standards: IEC/EN60947-2 Rated current: 63A, 80A, 100A(1P, 2P, 3P, 4P), 125A(1P, 2P); Rated voltage: 230V ~ (1P), 400V ~ (2P, 3P, 4P); Frequency: 50/60Hz Electromagnetic release type:C: 8In, D:12In Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In ≤ 100A); 4000 cycles (In > 100A); Rated short-circuit breaking capacity(Icu): 10kA;
NXB-125
Short-circuit breaking capacity(Ics): 7.5kA; Rated impulse withstand voltage(Uimp): 4kV;
RCCB
P 015 Low Voltage Brief Catalogue -
NL1
1. General
1.1 Function Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers are used in housing, tertiary sector and industry. 1.2 Detectable wave form AC class Tripping is ensured for slowly increasing sinusoidal AC residual currents. A class Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly. S, G/SI class Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. 1.3 Tripping sensitivity 10mA - precision instrument leakage protection and bathroom use. 30mA - additional protection against direct contact. 100mA - co-ordinated with the earth system according to the formula IΔn < 50/R, to provide protection against indirect contacts; 300mA/500mA - protection against indirect contacts, as well as fire hazard. Tripping time Instantaneous It ensures instantaneous tripping (without time-delay). Short time delay It ensures any tripping at least 10ms. Selective It ensures total discrimination with a nonselective RCD placed downstream With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.
NL1
NL1
2.Technical features
IEC/EN 62423 & IEC/EN 61008-1
Standard
IEC/EN 61008-1
AC, A
AC-G,A-G,A-SI
AC,A
F
Type (wave form of the earth leakage sensed)
63,80,100 AC-S,A-S
Rated current In Poles Rated voltage Ue
25, 40, 63
25, 40, 63
80,100
25,40,63
A
1P+N, 3P+N 230/400~240/415 0.01for1P+N 25A, 0.03, 0.1, 0.3, 0.5 0.03, 0.1, 0.3 0.03, 0.1, 0.3 0.1, 0.3
V
0.03, 0.1, 0.3
Rated sensitivity I△n Insulation voltage Ui Rated residual making and breaking capacity I△m Short-circuit current Inc=I△c SCPD fuse break time under I△n Rated frequency
V A
500 500 (In=25A/40A)
500 (In=25A/40A)
500 (In=25A/40A)
1000 (In=80A/100A) 1000(In=63A/80A/100A)
A
Electrical features
630 (In=63A)
630 (In=63A)
630 (In=63A)
6000/10000
10000
A A
10000
≤0.1(Normal type), 10ms~300ms(G type). 150ms~500ms(S type)
s Hz
6000 2 50/60
Rated impulse withstand voltage(1.2/50) Uimp Dielectric test voltage at ind. Freq. for 1 min Pollution degree
V
kV
2
RCCB
016 Low Voltage Brief Catalogue P -
From top and Bottom
RCCB
P 017 Low Voltage Brief Catalogue -
NXL-63 1. General
1.1 Function
Control electric circuits. Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers are used in housing, tertiary sector and industry. 1.2 Selection Detectable wave form AC class Tripping is ensured for slowly increasing sinusoidal AC residual currents. A class Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly. Tripping sensitivity 10mA - precision instrument leakage protection and bathroom use. 30mA - additional protection against direct contact. 300mA - protection against indirect contacts, as well as fire hazard. Tripping time Instantaneous It ensures instantaneous tripping (without time-delay)
NXL-63
NXL-63
2. Technical features
Standard
IEC/EN 61008-1
Rated current In Type (wave form of the earth leakage sensed) Poles Rated voltage Ue
AC, A
16, 25, 32, 40, 63
A
1P+N, 3P+N 230/400~240/415,110/200~127/220 0.01 (Only for 1P+N 16A, 25A),0.03,0.3 500 500 (In=16A/25A/32A/40A)
V A V
Rated sensitivity △ Insulation voltage Ui I n
Rated residual making and breaking capacity △ I m
A
Electrical features
630 (In=63A) 6000/1000 0
Short-circuit current Inc=I c △
A A s Hz V kV
10000
break time under △ Rated frequency SCPD fuse
≤ 0.1 50/60 6000
I n
Rated impulse withstand voltage(1.2/50) Uimp Dielectric test voltage at ind. Freq. for 1 min Pollution degree
2 2
2, 000 2, 000 Yes IP20
Electrical life Mechanical life Fault current indicator Protection degree Ambient temperature (with
Mechanical features
℃
-5...+40
daily average35 ) ≤ ℃ Storage temperation
℃
-25...+70
018 Low Voltage Brief Catalogue P - Low Voltage Brief Catalogue P-010
RCBO
RCBO
NB1L Residual Current Operated Circuit Breaker with Over-current Protection (Magnetic)
1. General
▪ Protection against risk of fire ▪ Protection against risk of electric shock
▪ Protection against overload ▪ Protection against short circuit ▪ Contact position indicator
2. Technical features
NB1L
IEC/EN 61009-1
Standard Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
AC, A
B, C
1, 2, 3, 4, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63 1~25/6~40 1P+N, 2P, 3P, 3P+N, 4P
MCB+add-on RCCB block Combined MCB+add-on RCCB block Combined
Rated current In
A
Poles
1P+N, 2P
Rated voltage Ue Rated sensitivity I △ n Rated short-circuit capacity lcn Break time under I △ n Electrical life Mechanical life
230/400~240/415
A V A s
6,000/10,000 ≤0.1 0.03, 0.1, 0.3
2,000 2,000
On DIN rail EN 60715 (35mm) by means of fast clip device From top and bottom (for combined type) From top (MCB+add-on RCCB block)
Mounting
Connection
3. Curve
B, C curve
t(s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2 1
0.5 0.2 0.1
0.05 0.02 0.01
0.005 0.002 0.001
0.5 1
2 34 5 7 10 20 30 5070100 200 I/In
RCBO
P 019 Low Voltage Brief Catalogue -
NB1L-40/63
1. General
▪Protection against risk of fire ▪ Protection against risk of electric shock ▪ Protection against overload ▪ Protection against short circuit ▪ Contact position indicator
NB1L-40/63
2.Technical features
Low Voltage Brief Catalogue RCBO
RCBO
P - 020
Low Voltage Brief Catalogue
P-017
NB310L Residual Current Operated Circuit Breaker with Over-current Protection (Magnetic)
1. General
� Protection against risk of fire � Protection against risk of electric shock
� Protection against overload � Protection against short circuit � Contact position indicator
2. Technical features
NB310L (2P)
IEC/EN 61009-1
Standard Type (wave form of the earth leakage sensed)
A, AC
A
3PN
2P
Poles
Thermo-magnetic release characteristic
B, C
6-40 3P+N 400
A
6-32 2P
Rated current In Poles
Rated voltage Ue Rated sensitivity I △ n Rated short-circuit capacity lcn Break time under I △ n Electrical life Mechanical life
230/240
A V A s
0.03
6,000 ≤ 0.1 2,000 2,000
10000
On DIN rail EN 60715 (35mm) by means of fast clip device From top and bottom
Mounting
Connection
3. Curve
NB310L (3PN)
B, C curve
t(s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2 1
0.5 0.2 0.1
0.05 0.02 0.01
0.005 0.002 0.001
0.5 1
2 34 5 7 10 20 30 5070100 200 I/In
RCBO
RCBO
P-016
P 021 Low Voltage Brief Catalogue -
Low Voltage Brief Catalogue
NB2LE Residual Current Operated Circuit Breaker
1. General
� Protection against risk of fire � Protection against risk of electric shock
� Protection against overload � Protection against short circuit
2. Technical features
NB2LE
IEC/EN 61009-1
Standard
Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
AC, A B, C
6, 10, 16, 20, 25, 32, 40 1P+N 240 0.03 6000
A
Rated current In Poles
Rated voltage Ue Rated sensitivity I △ n Short-circuit current Icn Electrical life Mechanical life
V A A
1,000 2,000
On DIN rail EN 60715 (35mm) by means of fast clip device
Mounting
From top and bottom
Connection
3. Curve
B, C curve
t(s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2 1
0.5 0.2 0.1
0.05 0.02 0.01
0.005 0.002 0.001
0.5 1
2 34 5 7 10 20 30 5070100 200 I/In
Low Voltage Brief Catalogue RCBO
P-011
RCBO
P - 022
Low Voltage Brief Catalogue
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
1. General
� Protection against risk of fire � Protection against risk of electric shock
� Protection against overload � Protection against short circuit � 1P+N in one module � Contact position indicator
NB3LE
2. Technical features
IEC/EN 61009-1
Standard
Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
AC, A B, C
6, 10, 16, 20, 25, 32 1P+N 240 0.03 6,000 ≤ 0.1
A
Rated current In
Poles Rated voltage Ue Rated sensitivity I △ n Break time under I △ n Short-circuit current Icn Electrical life Mechanical life Terminal connection type
V A A s
2, 000 2, 000
Cable/U-type busbar/Pin-type busbar
On DIN rail EN 60715 (35mm) by means of fast clip device
Mounting
From top
Connection
3. Curve
B, C curve
t (s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2
1
0,5 0,2
0,1
0,05 0,02 0,01
0,005 0,002 0,001
0,5 1
2 345 7 10 20 30 5070100 200 I/In
RCBO
RCBO
P-012
P 023 Low Voltage Brief Catalogue -
Low Voltage Brief Catalogue
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
1. General
� Protection against risk of fire � Protection against risk of electric shock
� Protection against overload � Protection against short circuit � 1P+N in one module � Contact position indicator
NB3LEU
2. Technical features
IEC/EN 61009-1
Standard
Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
AC, A B, C
6, 10, 13, 16, 20, 25, 32, 40, 45, 50 1P+N 240 0.03 10,000 ≤ 0.1
A
Rated current In
Poles Rated voltage Ue Rated sensitivity I △ n Break time under I △ n Short-circuit current Icn Electrical life Mechanical life Terminal connection type
V A A s
2, 000 2, 000
Cable/U-type busbar/Pin-type busbar
On DIN rail EN 60715 (35mm) by means of fast clip device
Mounting
Connection
From bottom
3. Curve
B, C curve
t (s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2
1
0,5 0,2
0,1 0,05 0,02 0,01
0,005 0,002 0,001
0,5 1
2 345 7 10 20 30 5070100 200 I/In
Low Voltage Brief Catalogue RCBO
P-013
RCBO
P - 024
Low Voltage Brief Catalogue
NB3LEG- 4 0 Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
1. General
▪ Protection against risk of fire ▪ Protection against risk of electric shock
▪ Protection against overload ▪ Protection against short circuit ▪ 1P+N in one module ▪ Contact position indicator
NB3LEG -4 0
2. Technical features
IEC/EN 61009-1
Standard
Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
AC, A B, C
6, 10, 13, 16, 20, 25, 32, 40 1P+N 230 - 240 0 . 01 , 0.03 6000 ≤ 0.1
A
Rated current In
Poles Rated voltage Ue Rated sensitivity I △ n Break time under I △ n Short-circuit current Icn Electrical life Mechanical life Terminal connection type
V A A s
2, 000 2, 000
Cable/U-type busbar/Pin-type busbar
On DIN rail EN 60715 (35mm) by means of fast clip device
Mounting
Connection
From bottom
3. Curve
B, C curve
t (s) 10000 5000 1h 2000 1000
B
500 200 100
50 20 10
C
5 2
1
0,5 0,2
0,1 0,05 0,02 0,01
0,005 0,002 0,001
0,5 1
2 345 7 10 20 30 5070100 200 I/In
RCBO
P 025 Low Voltage Brief Catalogue -
NB4LE Residual Current Operated Circuit Breaker (Electronic)
1. General 1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n =30mA, additional protection in the case of direct contact. RCD Type Type A RCD Type A is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase. Tripping curve B curve (3 In-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5 In-10 In) protection and control of the circuits
NB4LE
against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
Standard
IEC/EN 61009-1
Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
A
B, C 6, 10, 13, 16, 20, 25, 32
Rated current In Poles Rated voltage Ue
A
2P 230/240 0.03
A V
Rated sensitivity I△n Rated residual making and breaking capacity I△m Rated short-circuit capacity lcn Break time under I△n Rated frequency Rated impulse withstand voltage (1.2/50)Uimp
3,000
A
Electrical features
6,000 ≤0.1 50/60
s A Hz
kV
4
2 500 2 2,000 10,000
Dielectric TEST voltage at ind. Freq. for 1min Insulation voltage Ui Pollution degree Electrical life Mechanical life Contact position indicator Protection degree
kV V
Yes
Mechanical features
IP20
Ambient temperature (with daily average≤35℃)
-25~+40
℃
Storage temperature
-25~+70
℃
2. Technical data 2.1 Curves
t(s)
B Curve
C Curve
t(s)
10000 5000 2000 1000 1h
10000 5000 2000 1000 1h
500 200 100
500 200 100
50 20 10
50 20 10
5 2
5 2
1
1
0.5 0.2 0.1
0.5 0.2 0.1
0.05 0.02 0.01
0.05 0.02 0.01
0.005 0.002 0.001
0.005 0.002 0.001
0.5
1
2
3
4
5
7
10
20
30
50
70
100
200
1/In
1/In
0.5
1
2
3
4
5
7
10
20
30
50
70
100
200
RCBO
RCBO
P-014 P - 026
Low Voltage Brief Catalogue Low Voltage Brief Catalogue
NBH8LE Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
1. General
▪ Protection against risk of fire ▪ Protection against risk of electric shock
▪ Protection against overload ▪ Protection against short circuit
2. Technical features
NBH8LE
IEC/EN 61009-1
Standard
Type (wave form of the earth leakage sensed) Thermo-magnetic release characteristic
AC C
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40 1P+N 230/240 0.01, 0.03 4,500/6,000
A
Rated current In Poles
Rated voltage Ue Rated sensitivity I △ n Short-circuit current Icn Electrical life Mechanical life
V A A
20, 000 4,000
On DIN rail EN 60715 (35mm) by means of fast clip device
Mounting
From top
Connection
3. Curve
C curve
t(s) 10000 5000 1h 2000 1000
500 200 100
50 20 10
5 2
1
0.5 0.2
0.1 0.05 0.02 0.01
0.005 0.002 0.001
0.5 1
2 3 45 7 10 20 30 50 70100 200 I/In
RCBO
P 027 Low Voltage Brief Catalogue -
NB8LE-63M
1. General
1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. Selection Rated residual operating current I ∆ n = 30mA, additional protection in the case of direct contact. RCD Type Type A RCD Type A is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase. Tripping curves C curve (5-10In) protection for resistive and inductive loads with low inrush current. D curve(10-16In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
NB8LE-63M
2. Technical features
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91 Page 92 Page 93 Page 94 Page 95 Page 96 Page 97 Page 98 Page 99 Page 100 Page 101 Page 102 Page 103 Page 104 Page 105 Page 106 Page 107 Page 108 Page 109 Page 110 Page 111 Page 112 Page 113 Page 114 Page 115 Page 116 Page 117 Page 118 Page 119 Page 120 Page 121 Page 122 Page 123 Page 124 Page 125 Page 126 Page 127 Page 128 Page 129 Page 130 Page 131 Page 132 Page 133 Page 134 Page 135 Page 136 Page 137 Page 138 Page 139 Page 140 Page 141 Page 142 Page 143 Page 144 Page 145 Page 146 Page 147Powered by FlippingBook