CHINT'S Low Voltage Brief Catalogue

Modular Din Rail Product NXBLE-40 Residual current operated circuit breaker Modular Din Rail Product

030 Low Voltage Brief Catalogue P -

P-083

Low Voltage Brief Catalogue

▪ Compliant standards: IEC61009-1 ▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ▪ Rated residual operating current: 0.01A, 0.03A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 4500A ▪ Compliant standards: IEC61009-1 ▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A ▪ Rated residual operating current: 0.01A, 0.03A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 4500A ▪ Short-circuit breaking capacity(Ics): 4500A ▪ Rated impulse withstand voltage(Uimp): 4kV

NXBLE-63Y Residual current operated circuit breaker

NXBLE-40

NXBLE-63Y

▪ Short-circuit breaking capacity(Ics): 4500A ▪ Rated impulse withstand voltage(Uimp): 4kV

NXBLE-40 Residual current operated circuit breaker NXBLE-125 Residual current operated circuit breaker

▪ Compliant standards: IEC61009-1 ▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A ▪ Rated residual operating current: 0.01A, 0.03A ▪ Rated voltage: 240/415V ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N ▪ Mechanical life: 20000 cycles ▪ Electrical life: 10000 cycles ▪ Rated short-circuit breaking capacity(Icu): 4500A ▪ Short-circuit breaking capacity(Ics): 4500A ▪ Rated impulse withstand voltage(Uimp): 4kV Modular Din Rail Product ▪ Compliant standards: IEC60947-2 ▪ Rated current: 63A, 80A, 100A, 125A ▪ Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A ▪ Rated voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P) ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In> 100A) ▪ Rated short-circuit breaking capacity(Icu): 10000A ▪ Short-circuit breaking capacity(Ics): 7500A ▪ Rated impulse withstand voltage(Uimp): 4kV

NXBLE-125

NXBLE-40

P-084

Low Voltage Brief Catalogue

▪ Compliant standards: IEC60947-2 ▪ Rated current: 63A, 80A, 100A, 125A ▪ Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A ▪ Rated voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P) ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: C, D ▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In> 100A) ▪ Rated short-circuit breaking capacity(Icu): 10000A AX-X1 Auxiliary contacts 、 AL-X1 Alarm auxiliary contact NXBLE-125 Residual current operated circuit breaker ▪ Compliant standards: IEC61009-1 ▪ Rated current: 63A, 80A, 100A, 125A ▪ Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A ▪ Rated voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P) ▪ Frequency: 50/60Hz ▪ Electromagnetic release type: B, C, D ▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P ▪ Mechanical life: 20000 cycles ▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A) ▪ Rated short-circuit breaking capacity(Icu): 10000A NXBLE-125G Residual current operated circuit breaker ▪ Short-circuit breaking capacity(Ics): 7500A ▪ Rated impulse withstand voltage(Uimp): 4kV

NXBLE-125G

NXBLE-125

▪ Short-circuit breaking capacity(Ics): 7500A ▪ Rated impulse withstand voltage(Uimp): 4kV ▪ Compliant standards: IEC 60947-5-1 ▪ Rated insulation voltage (Ui): 500V ▪ Utilization category:AC-12,DC-12 ▪ Rated operation current under different rated operation voltage: AC-12:240V/6A,415V/3A;

AX-X1