CHINT'S Low Voltage Brief Catalogue

Contactor,Overload Relay Motor Control & Protection

Low Voltage Brief Catalogue 066 Low Voltage Brief Catalogue P - P-034

P-087

Low Voltage Brief Catalogue

CJ19 Capacitor Switching Contactor NXC AC Contactor

� The CJ19 Series Contactor is used in remote capacitor (130kvar) switch application. � Rating up to 400V, 130A (AC-6b). ----- (25A, 32A, 43A, 63A, 95A,115A,150A,170A) ▪ The NC1 series AC contactor is used in remote motor (≤335kW) control application. ▪ Rating up to 690V, 630A (AC-3). ------(6A, 9A, 12A, 16A, 18A, 22A, 25A, 32A, 38A, 40A, 50A, 65A, 75A, 85, 100A, 120A, 160A, 185A, 225A, 265A, 330A, 400A, 500A, 630A) � Standard: IEC/EN 60947-4-1 � Ambient temp: -5℃~+40℃ � Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V CJ19-25: Rating current 17A (AC-6b/380V); Power of controlled capacitor � 12.5kvar. CJ19-32: Rating current 23A (AC-6b/380V); Power of controlled capacitor � 20kvar. CJ19-43: Rating current 29A (AC-6b/380V); Power of controlled capacitor � 25kvar. CJ19-63: Rating current 43A (AC-6b/380V); Power of controlled capacitor � 33.3kvar. CJ19-95: Rating current 72.2A (AC-6b/400V); Power of controlled capacitor � 50kvar. CJ19-115: Rating current 87A (AC-6b/400V); Power of controlled capacitor � 60kvar. CJ19-150: Rating current 115A (AC-6b/400V); Power of controlled capacitor � 80kvar. CJ19-170: Rating current 130A (AC-6b/400V); Power of controlled capacitor � 90kvar. ▪ Standard: IEC/EN 60947-4-1 ▪ Ambient temp.: -35℃~+70℃ ▪ Coil voltage : 6A~225A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC) 265A~630A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC/DC) 6A~12A (mini type): 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC) 24V, 48V, 110V, 220V (DC) ▪ Side mounting auxiliary contacts: AX-3C/11 ( for 6A~225A) & AX-3C/11B (for 265A~630A) (1NO&1NC) ▪ Top mounting auxiliary contacts: AX-3X/11 & AX-3X/20 & AX-3X/02 (1NO&1NC or 2NO or 2NC) AX-3X/13 & AX-3X/31 (1NO&3NC or 3NO&1NC) AX-3X/22 & AX-3X/40 & AX-3X/04 (2NO&2NC or 4NO or 4NC) AX-3M/11 & AX-3M/20 & AX-3M/02 (for mini type, 1NO&1NC or 2NO or 2NC) AX-3M/13 & AX-3M/31 (for mini type, 1NO&3NC or 3NO&1NC) AX-3M/22 & AX-3M/40 & AX-3M/04 (for mini type, 2NO&2NC or 4NO or 4NC) ▪ Top mounting time delay block: F5-T (making time delay) & F5-D (breaking time delay) ▪ Assemble with Thermal Overload Relay NXR to be a DOL Starter. ▪ Assemble with another one to be a reversing contactor.

CJ19 NXC

NR8 Thermal Overload Relay

▪ NR8 series thermal overload relay is used to provide overload and phase failure protection for AC motors ▪ Frequency: AC 50Hz/60Hz NXR Thermal Overload Relay

▪ Voltage: up to 690V ▪ current: 0.1A~38A ▪ Standard: IEC 60947-4-1. ▪ The NXR series thermal overload relay is used to provide overload and phase failure protection for AC motors. ▪ Rating up to 690V, 630A (AC-3): ------ (12A for mini type, 25A, 38A, 100A, 200A, 630A) ▪ NXR-200 and NXR-630 are electronic overload relay.

NR8

▪ Standard: IEC/EN 60947-5-1 ▪ Ambient temp.: -35℃~+70℃ ▪ Assemble with NXC contactor to be a DOL starter.

NXR

NRE8 Electronic Overload Relay

� The NRE8 Series Electronic Overload Relay is used in remote motor control application for overload function. � Rating up to 690V, 630A (AC-3). ----- (25A, 40A, 100A, 200A, 630A) � Standard: IEC/EN 60947-4-1 � Ambient temp: -5℃~+40℃ � Assemble with Contactor NC1, NC2, NC7,NC8 to be a DOL Starter.

NRE8