CHINT Water Meters

LXSGY photoelectric direct reading water meter

1. Product overview Photoelectric direct reading water meter is a kind of water meter that uses photoelectric direct reading

technology to read the data of the word wheel. It has no error in reading and strong anti-interference ability. It is

designed with low power consumption and uses M-BUS to copy the water consumption.

2. Product features ● By using the unique direct reading coding technology, the position state of the counter wheel is read directly at the moment of meter reading, and then it is transmitted to the system background after decoding, and the same value as the water meter window is displayed on the meter reading interface. Free from the influence of time, environment and backflow, and truly achieve zero error. ● Power supply is not needed at daily life, but only at the moment of meter reading, and the service lifetime is long. ● There is no physical contact between the direct reading sensor and devices such as counters, which does not affect the metering accuracy. ● EMC test meets the requirements of national standards, and overcomes the problem that the accuracy and stability of direct reading water meters are affected by external electromagnetic interference. ● Unique address code: each meter has a unique address code belonging to this table, which is convenient for management and maintenance. ● Error protection: there are error protection devices for bus open circuit, short circuit and idle.

3. Technical parameter

Performance Temperature class: cold water meter: T30; Hot water meter: T90

Climate and mechanical environment class: B

Pressure class: MAP10

Electromagnetic environment class: E1

Pressure loss class : Δp63

Protection class: IP68

Upstream flow field Sensitivity class: U10

Accuracy class: class 2

Downstream flow field sensitivity class: D5

Nominal caliber DN(mm)

Range ratio R (Q3 /Q1 )

Overload flow Q4 ( m³ /h)

Common flow Q3 ( m³ /h)

Boundary flow Q2 ( m³ /h)

Minimum flow Q1 (m³ /h)

DN15

100

3.125

2.5

0.040

0.025

DN20

100

5.0

4.0

0.064

0.040

DN25

100

7.875

6.3

0.1008

0.063

DN32

100

12.5

10

0.160

0.100

DN40

100

20

16

0.256

0.160

DN50

100

31.25

25

0.400

0.250

4. Dimension

Length L1 (mm)

Length L (mm)

Nominal diameter DN(mm)

Width B (mm)

Height h (mm)

Connecting thread (D)

Connecting thread (d)

15

165

258

98

104

G3/4B

R1/2

20

195

294

98

106

G1B

R3/4

25

225

345

112

G11/4B

R1

103

32

230

350

104

117

G1′1/2B

R1′1/4

40

245

369

124

147

G2B

R1′1/2

Length L1 (mm)

Nominal diameter DN(mm)

Width B (mm)

Height h (mm)

Adapting flange

Outer diameter D

Central diameter D1 of bolt hole

Number and specification of connecting bolts

50

285

160

195

160

125

4×M16

Accurate measurement and intelligent IOT > > 07