CHINT EnergiX-P40 Brochure
ABOUT CHINT
CHINT A leading global provider of smart energy solutions
Main Businesses
Low-voltage Apparatus
Power Transmission and Distribution
Instrumentation and Apparatus
Intelligent Building
Clean Energy
Smart Home
Home Electrical Apparatus
Industry Automation
Intelligent Manufacturing
Smart Heating
Smart Water
GLOBAL FOOTPRINT
Netherlands
Germany
Poland
The Czech Republic
Frankfurt
Kazakhstan
North America
Romania i
Italy Spain
Europe
Turkey
U.S.A.
Xianyang Jinan
Los Angeles
Cairo
Yancheng
Algeria
Egypt
Shanghai
Wenzhou Hangzhou
Jiaxing
Mexico
U.A.E.
Asia P
India
Western Asia and Africa
Thailand
Cambodia
Vietnam
Malaysia
Colombia
Singapore
R&D center
Indonesia
Peru
Latin America
Manufacturing base International marketing territory
Brazil
Chile
4
6
and Africa, Europe, Latin America, North America, China
North Africa
17
Manufacturing Bases: China (Wenzhou, Hangzhou, Shanghai, Jiaxing, Xianyang, Jinan, Yancheng, Shenyang, Wuhan), Thailand, Singapore, Vietnam, Malaysia, Egypt, Uganda, Algeria and Cambodia.
20+
2300+
International Logistics Centers
Sales Companies
GLOBAL CAPACITY LAYOUT
The industrial manufacturing bases are mainly located in Wenzhou, Hangzhou, Shanghai, Jiaxiang, Xianyang and Yancheng. Additionally, CHINT has set up factories in China (Jinan, Shenyang, Wuhan), Thailand, Singapore, Vietnam, Malaysia, Egypt, Uganda, Algeria, Cambodia etc.
Wenzhou Manufacturing Base
Hangzhou Manufacturing Base
Shanghai Manufacturing Base
Jiaxing Manufacturing Base
Xianyang Manufacturing Base
Yancheng New Energy Manufacturing Base
Singapore Complete Electric Equipment Manufacturing Base
Wuhan Manufacturing Base
Jinan Cable Manufacturing Base
Vietnam Manufacturing Base
Thailand Solar Power Manufacturing Base
Malaysia Manufacturing Base
Egypt Manufacturing Base
Algerian Manufacturing Base
Cambodia Manufacturing Base
EnergiX-P40 catalogue
1.0
Applications
The world is entering the digital era at a faster speed than expected. Digital priority has become the core of the new needs of enterprises after the pandemic. More than 86% of the enterprises in the world will carry out digital transformation. By 2024, more than 51% of the global IT budget will be put in digital innovation/ transformation, while for China, this number will be over 70%. AI, cloud computing, 5G, streaming media and IOT drive the demand for larger data storage, stronger data computing ability and faster data interaction. As the key infrastructure and physical carrier in the digital era, data center has gradually changed from cost center to service center, from supporting business development to driving business development, and has become the accelerator of business innovation. Data center construction is a complex system engineering. From initial design and planning to the project construction, and then to the installation of supporting facilities and later operation and maintenance services, every components need to be connected and complement each other. 1HZWHFKQRORJLHVQHZVHUYLFHVDQGQHZDSSOLFDWLRQVDUHSURIRXQGO\DŴHFWLQJWKHFRQVWUXFWLRQPRGHDQG2 0PRGHRIWKHQHZJHQHUDWLRQ cloud data center, which poses new challenges to the design concept, construction standards, delivery speed, network structure
Data center topology diagram
IT Equipment (Critical load)
PDU A
PDU A
Mechanical Load (Cooling)
LV Switchgear
LV Switchgear
UPS N
UPS +1
UPS N
UPS +1
Switchgear
Switchgear
Gen Switchgear
Main Switchgear
Gen Switchgear
Main Switchgear
G ~ N
G ~ N
G ~ N
G ~ N
Utility food A
Utility food B
+
+
Diesel Generator
T4 (Level A)
2 Mains
UPS
Value to the customer
Safety
Customization
Durability
The product has passed IEC 61439-2 type test and seismic test to ensure the safety of personnel. The high breaking capability can break 15kA fault currents
Flexible cables entry/exit type" and modular structure layout to meet customization needs
IP31 and corrosion protection process allow the PDU to be used outside the equipment room
5 | CHINT
EnergiX-P40 catalogue
2.0
Advantages
MCCB 50kA MCB 15kA
High breaking capability. A. Using the reliable and safe busbar system scheme to ensure the safe operation of user load
B. Modular design Each functional unit is separated from each other Multilevel layout for easy daily operation Flexible entry and exit scheme Independent installation space for BMS
Modular design
144 Number of outgoing circuits
C. High power capacity 144 number of outgoing circuits, Saving equipment room space
D. Live-Swappable Outgoing circuits : Common MCB compatible Support live plug, remove and replace components
Live swappable
E. Smarter EnergiX-P40 Optional branch control monitoring system,which collect every circuits electrical parameter
BCM & EPMS
CHINT | 6
EnergiX-P40 catalogue
3.0
Product introduction
3
1
4
2
5
6
1
2
New label ͆
1850*445 main window͆ Observe MCB ON/OFF status ͆ Observe meter parameter
Delicate and beautiful
3
4
Using cable gland͆
Lock with padlock͆ Meet data center requirements͆ Prevent non-professionals from misoperation
IP 31͆ 6XLWDEOHIRUGLŴHUHQWVL]HVRIFDEOHV
5
6
1850*205 window͆
Base with a heat sink 100mmͤ
Observe BMS parameter
7 | CHINT
EnergiX-P40 catalogue
3.0
Product introduction
5
1
2
6
3
4
1
2
Door panel opening design͆ Operate the circuit breaker and meter without opening the inner door
Detachable door panel͆
Meet the requirements of open door IP20
3
4
Lights ( Status ON/OFF )͆
Circuits number label
Observe MCB ON/OFF status
5
6
File cover
Branch circuit power monitoring͆ Supports 144 circuits electrical monitoring͆ With local display, remote transmission function
CHINT | 8
EnergiX-P40 catalogue
3.0
Product introduction
1
3
2
4
1
2
NM8N MCCB͆
Double busbar system design͆ Live-Swappable͆ Icu=5/10/15kA
ICU=50kA
3
4
N͡ PE bar
Terminal͆
Using UK40 terminal
9 | CHINT
EnergiX-P40 catalogue
3.0
Product introduction
Busbar System
7KHGLVWULEXWLRQVWUXFWXUHRIWKHV\VWHPLVFRPSDFW,WLVHDV\WRLQVWDOODQGUHSODFHFRPSRQHQWVZKLFKVLJQLnFDQWO\UHGXFHVWKHVSDFHUHTXLUHPHQW for installing PDUs in the equipment room.
The busbar system is the ideal solution for distribution boards with a rated current up to 360 A. The installation height of just 145 mm allows a particularly compact system to be realized The system breaking capacity up to 30kA to protect IT loads from fault currents. Hot swappable busbar system, meet the requirements for quick operation and maintenance.
Busbar System
Hot swappable busbar system
1
2
Quick installation and maintenance
Installation height 145mm
3
4
Component
MCB —— NB1-63H Miniature Circuit Breakers according to IEC/EN 60898-1 Ѳ IEC/EN 60947-2 Ѳ UL1077 Rated short circuit breaking capacity 10 kA 1 up to 4-pole versions Tripping characteristics B, C, D Rated current up to 63 A Rated operational voltage 230/400~240/415AC, 110/125 DC
CHINT | 10
EnergiX-P40 catalogue
3.0
Product introduction
MCB —— Ex9BH (A CHINT company brand) Miniature Circuit Breakers according to IEC/EN 60898-1 and IEC/EN 60947-2 (partially) Rated short circuit breaking capacity 15 kA 1 up to 4-pole versions Tripping characteristics B, C, D Rated current up to 63 A Rated operational voltage 240/415 V AC, 48 V DC (per pole)
SPD —— NU6-III
Electric ratings: Single phase power distribution and control System of AC50Hz, 230V Short circuit current: Up to 10kA Apparatus: Protect electric system and on-loading electrical Apparatus from lightening and instantaneous over-voltage Standard : IEC61643-1, EN61643-11
Power Quality & Energy Meter
It can measure three phase current, voltage, active/reactive power, power factor, frequency, positive/ negative active energy, four-quadrant reactive energy With the standard RS-485 communication interface, adopting the standard ModBus-RTU communication protocol and the baud rate can be set with switch quantity input function Function extension: Four-way analog quantity output function; four-way switching quantity output function “remote-communication” and “remote control” functions Parameters such as the current/voltage ratio, indication mode for electrical quantity, the of the meter, electric quantity display mode, communication address of the meter, baud rate, transmitting output object, transmitting output range, alarming object, alarming upper/lower limit, etc. can be randomly programmed and set
Intelligent Branch Circuit Power Monitoring System
Measurement accuracy according toIEC62053-22 Cl 0.5S Measure up to 2 main circuits up to 31st harmonics measurements Measure up to 24 single phase circuits or measure up to 8 three phase sub-circuit metering Able to combine either three phase or single phase according to your need 4 relays output Optional with 2nd Modbus output Designed to suit with split core current transformer with 333mV CT input (CT range from 100A to 3000A)
11 | CHINT
EnergiX-P40 catalogue
3.0
Product introduction
IBCPM Characteristics
Communication / Interface
RS-485: Modbus-RTU (Default) / Optional Modbus TCP
Physical interface
RS-485
Communication speed
Up to 38.4 kbps
Communication protocol
Modbus-RTU / Optional Modbus TCP
Measurement Parameters
Power Quality Analysis
Wave Sampling
128 samples/cycle
Harmonic
31st Harmonic (Main Circuits)
Alarm setting
Setpoint alarm and record
Voltage, Current, Active power, Reactive Power, Apparent Power, Power Factor, Frequency, THD
Real-time Data
Measurement Channel
2 main circuits and 24 channels sub circuits
Memory Record
Memory
2MB
/RDGVHWWLQJIURPSUHYLRXVVDYHGnOHRUVHW Rated range 50 - 600V (L-L) according to needs.
Setting
Accuracy
Voltage/ Current
±0.2%
Re-,Active/Apparent power
±0.2%
Active Energy
±0.5%
Reactive Energy
±0.5%
Power Factor
±0.5%
Frequency
±0.1%
THD
1%
Unbalance
±0.5%
CHINT | 12
EnergiX-P40 catalogue
3.0
Product introduction
Power monitoring system
Chint provides complete loading background monitoring solution: Complete parameter information enables users to monitor of each circuit Wiring be done by serial Ϫ adding communication device easily Modbus communication protocol Ϫ 6XSSRUWFXVWRPHUWRGHnQHFRPPXQLFDWLRQGHYLFHEUDQG
Chint PMS communication scheme
I/O
TCP/IP
RS485
ETHERNET INTERFACE
EPMS PANEL
I/O
TCP/IP
RS485
ETHERNET INTERFACE
EPMS PANEL
RS485
....
RS485
RS485
....
....
13 | CHINT
EnergiX-P40 catalogue
3.0
Product introduction
Chint PMS parameter list
PDU BRANCH CIRCUIT MONITORING
DIGITAL POWER METER
1. Voltage (L1-N) 2. Voltage (L2-N) 3. Voltage (L3-N) 4. Voltage (L1-L2) 5. Voltage (L2-L3) 6. Voltage (L1-L3) 7. Current (L1) 8. Current (L2) 9. Current (L3) 10. Frequency 11. Real Power (kW)
1. Voltage A-B RMS 2. Voltage B-C RMS 3. Voltage C-A RMS 4. Voltage L-L Average RMS 5. Voltage A-N RMS 6. Voltage B-N RMS 7. Voltage C-N RMS 8. Voltage L-L Average RMS 9. Frequency 10. Current A RMS 11. Current B RMS 12. Current C RMS 13. Current Average RMS
12. Reactive power (kVAr) 13. Apparent power (KVA) 14. Power factor
14. Current A RMS Peak - Last Minute 15. Current B RMS Peak - Last Minute 16. Current C RMS Peak - Last Minute
15. Max power demand (kW) (L1) 16. Max power demand (kW) (L2) 17. Max power demand (kW) (L3)
17. Power Factor A 18. Power Factor B 19. Power Factor C 20. Power Factor Total 21. Real Power Total RMS
22. Reactive Power Total RMS 23. Apparent Power Total RMS 24. Real Energy Total 25. Reactive Energy Total 26. Apparent Energy Total 27. High Priority Alarm Present
CHINT | 14
EnergiX-P40 catalogue
4.0
3URGXFWFHUWLnFDWLRQ
77$FHUWLnFDWLRQ
Temperature rise limits Comply with IEC 61439-2 : 2020-10.10
Degree of protection
Comply with IEC 61439-2 : 2020-10.3 • Form 2b IP31
Seismic report
Mechanical test
Mechanical operation Degree of protection
Seismic report
15 | CHINT
EnergiX-P40 catalogue
4.0
3URGXFWFHUWLnFDWLRQ
Strength of material and parts Comply with IEC 61439-2 : 2020-10.2 Resistance to corrosion Properties of insulating materials Thermal stability 5HVLVWDQFHORDEQRUPDOKHDWDQGnUHGXHWRLQWHUQDOHOHFWULFHŴHFWV Lifting Mechanical operation
Icc Test Comply with IEC 61439-2-2020-10.11 Main busbar, Outgoing circuits15kA Incoming circuits 50kA
Comply with IEC 60068-3-3: 2019: Dielectric properties Electrical connectivity Seismic test
CHINT | 16
EnergiX-P40 catalogue
5.0
Characteristics
Electrical characteristics
Mechanical Characteristics
Rated current (In)
400A/200A
H*W*D(mm)
450kg
Rated power capacity(Pn)
277kVA@400V/138kVA@400V Weightͧ Including deviceͨ
Rate voltage(Un) & (Ue)
230/400V±5ͤ
Color
RAL 7021 mate
Degree of protection (Closed/open doorsͨ
Rated insulation voltage(Ui)
690 Vac
IP 31/IP 20
Uimp
6kV
Front door type
Lexan window door
Safety door w/ direct access to Branch Circuit Monitoring
Icc MCCB/MCB
50kA/15kA
Weightͧ Including deviceͨ
Frequency
+]
Cables entry/exit
Top
Number of poles
3Ph+N+PE
Maintain type
Front
Operating temperature
0 ȭ -40 ȭ
corrosion prevention
sea salt spray test
Storage temperature
-25 ȭ ~+70 ȭ
Form
Form 2B
Display*
HMI
Hot swappable MCB
Y
Power Monitoring System*
Conventional or Branch circuit monitoring as required
Standards
Communication/Monitoring*
77$FHUWLnFDWH
IEC 61439-2
1. Status ON/OFF 2. Voltage (V) 3. Current (A) 4. Apparent Power (kVA) 5. Real Power (kW) 6. Reactive Power (kVAr) 7. Power factor 8. Energy (kWhr) 9. Frequency
Metered values
Seismic test
IEC 60068-3-3
Branch monitoring accuracy
ð
Communication
Modbus RS485
17 | CHINT
CHINT | 18
Asia Pacific
China Zhejiang CHINT Electrics Co., Ltd.
Indonesia PT. CHINT Indonesia
Add (Shanghai): A3 Building, No. 3655 Sixian Road, Songjiang 201614 P.R.China Tel: +86-21-67777706 Fax: +86-21-67777777-88225 Email: Global-Sales@CHINTGlobal.com Web: www.CHINTGlobal.com
Add: Kompleks Prima Center I, Blok C9-10, Jl. Pesing Poglar Jl. Pool PPD No. 11, RT.9/RW.2, Cengkareng, Jakarta Barat Tel: +62 21 5436 3000
Email: Sales@CHINT-Indonesia.com Web: www.CHINT-Indonesia.com
Korea CHINT Electric Korea Co.,LTD
Singapore | APAC HQ CHINT Global International Pte Ltd
Add: B501, 40, Imiro, Uiwang-Si, Gyeonggi-Do, KOREA 16006 Tel: +82 31 8068 7099
Add: 8 Kallang Avenue, #04-06/09 Aperia Office Tower 1, Singapore 339509
Email: Lrning@CHINT.com Web: www.CHINTGlobal.kr
Tel: +65 6329 3110 Fax: +65 6329 3159
Email: Sales.APAC@CHINT.com Web: www.CHINTGlobal.com
Malaysia Alpha Automation (Selangor) Sdn. Bhd.
Sunlight Electrical Pte Ltd
Add: No. 11, Temasya 18, Jalan Pelukis U1/46B, Seksyen U1, 40150 Shah Alam, Selangor, Malaysia
Add: 1 Third Chin Bee Road, Singapore 618679 Tel: +65 6741 9055 Fax: +65 6265 4586 Email: Sales@SunlightGroup.com Web: www.SunlightGroup.com
Tel: +603-5569 7787 Fax: +603-5569 9295 Email: CHINTMalaysia@AlphaSel.com Web: www.AlphaSel.com
Philippines CHINT Electric Co., Ltd
Cambodia CHINT (Cambodia) Power Equipment Co., Ltd
Add: Unit 201, Taipan Place, F. Ortigas Jr. Road, Ortigas Center, Pasig City, Metro Manila, Philippines Tel: +63 967 273 0174 / +63 977 017 6320 Email: Liq07@CHINTGlobal.com / Wencell@CHINTGlobal.com Web: www.CHINTGlobal.com
Add: No.15, St. 542, Sangkat Boeung Kok 1, Khan Toul Kork, Phnom Penh, Cambodia Tel: +855 23 231 077 Email: lbin3@CHINTGlobal.com Web: www.CHINTGlobal.com
Vietnam CHINT Vietnam Holding Co., Ltd
SchneiTec CHINT Co., Ltd
Add: Ansor Kdam Village, Sna Ansa Commune, Krakor District, Pursat Province, Cambodia Tel: +855 09 5353 268 Email: Liubin@SchneiTec-CHINT.com.kh / Info@SchneiTec-CHINT.com.kh Web: www.SchneiTec-CHINT.com.kh
Add: So 2Bis-4-6, Le Thanh Ton, P. Ben Nghe Quan 1, Ho Chi Minh, Vietnam Tel: +84 0283 8270 015 Email: Marketing.VN@CHINTGlobal.com Web: www.CHINTGlobal.vn
India CHINT India Energy Solution Private limited
Sunlight Electrical (VN) Co., Ltd
Add: 20 Doc Lap Ave, VSIP, Thuan An City, Binh Duong Province, Vietnam Tel: +84 0274 3743 505 Email: Sales.Sev@SunlightGroup-VN.com.vn Web: www.SunlightVietnam.com.vn
Discovery Tower Plot No A-17, Ground Floor, Sector – 62 Noida – 201309 Tel: +91 1202 9750 57 Email: Marketing@CHINT.co.in Web: www.CHINT.co.in
Tel: +65 6329 3110 Email: Sales.APAC@CHINT.com Web: www.CHINTGlobal.com
CHINT GLOBAL INTERNATIONAL PTE LTD 8 Kallang Avenue, #04-06/09 Aperia Office Tower 1, Singapore 339509
Printed by CHINT Global. No part of this brochure may be used or reproduced in any manner whatsoever without written permission. CHINT is the only publisher that can modify or change the content.
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20Powered by FlippingBook