� Protection against short circuit � Contact position indicator
2. Technical features
NB310L (2P)
Low-voltage Brief Catalogue
Low-voltage Brief Catalogue
RCCB
RCCB
015
016
P -
P -
IEC/EN 61009-1
Standard Type (wave form of the earth leakage sensed)
A, AC
A
NL1
NL210 Residual Current Operated Circuit Breaker without over-current protection B, C Thermo-magnetic release characteristic Poles 2P 3PN
6-40 3P+N 400
A
6-32 2P
Rated current In Poles
1. General
1. General Rated voltage Ue Rated sensitivity I △ n Rated short-circuit capacity lcn Break time under I △ n Electrical life Mechanical life
230/240
A V A s
1.1 Function Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers are used in housing, tertiary sector and industry. 1.2 Detectable wave form AC class Tripping is ensured for slowly increasing sinusoidal AC residual currents. A class Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly. S, G/SI class Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. 1.3 Tripping sensitivity 10mA - precision instrument leakage protection and bathroom use. 30mA - additional protection against direct contact. 100mA - co-ordinated with the earth system according to the formula IΔn < 50/R, to provide protection against indirect contacts; 300mA/500mA - protection against indirect contacts, as well as fire hazard. Tripping time Instantaneous It ensures instantaneous tripping (without time-delay). Short time delay It ensures any tripping at least 10ms. Selective It ensures total discrimination with a nonselective RCD placed downstream With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.
0.03
• Protect people against indirect contacts and additional protection against direct contacts. • Protect installations against fire hazard due to insulation faults. 6,000 ≤ 0.1
2,000 2,000
10000
2. Detectable wave form
On DIN rail EN 60715 (35mm) by means of fast clip device From top and bottom
Mounting
NL1
• B Class Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
Connection
3. Curve
NB310L (3PN)
B, C curve
3. Tripping sensitivity
t(s) 10000 5000 1h 2000 1000
30mA-additional protection against direct contact.
B
500 200 100
4. Tripping time
50 20 10
• Instantaneous It ensures instantaneous tripping (without time-delay).
NL1
C
5 2 1
0.5 0.2 0.1
5. Fault current indicator
NL210
0.05 0.02 0.01
6. Technical features
0.005 0.002 0.001
Standard
IEC/EN 61008-1
0.5 1
2 34 5 7 10 20 30 5070100 200 I/In
Type (wave form of the earth leakage sensed)
B
Rated current In
A 25, 40, 63
Poles
4P
Rated voltage Ue
V 400
Rated sensitivity I △ n
A 0.03
2. Technical features
Short-circuit current Icn=I △ c
A 10000
Electrical life
2,000
IEC/EN 62423 & IEC/EN 61008-1
Standard
IEC/EN 61008-1
Mechanical life
10000
Type (wave form of the earth leakage sensed)
AC, A
AC-G, A-G, A-SI
AC, A
AC-S, A-S
F
Terminal connection type
Cable/U-type busbar/Pin-type busbar
Rated current In
A 25, 40, 63
25, 40, 63
80, 100
63, 80, 100
25, 40, 63
Mounting
On DIN rail EN 60715 (35mm) by means of fast clip device
Poles
1P+N, 3P+N
Rated voltage Ue
V
230/400~240/415 0.01for1P+N 25A, 0.03, 0.1, 0.3, 0.5
Connection
From top and Bottom
Rated sensitivity I △ n
A
0.03, 0.1, 0.3 0.03, 0.1, 0.3 0.1, 0.3
0.03, 0.1, 0.3
Insulation voltage Ui
V 500
500 (In=25A/40A) 500 (In=25A/40A) 1000
500 (In=25A/40A)
Rated residual making and breaking capacity I △ m
1000 (In=63A/80A/100A)
Electrical features
A
(In=80A/100A)
630 (In=63A) 6000/10000
630 (In=63A)
630 (In=63A)
Short-circuit current Inc=I △ c
A A
10000
SCPD fuse
10000
Break time under I △ n
s ≤0.1(Normal type), 10ms~300ms(G type). 150ms~500ms(S type)
Rated frequency
Hz 50/60
Rated impulse withstand voltage(1.2/50) Uimp V 6000 Dielectric test voltage at ind. Freq. for 1 min kV 2 Pollution degree 2