CHINT Low-voltage Brief Catalogue

Contactor Contactor

Contactor,Overload Relay

P-033 P -

P-034 068

Low Voltage Brief Catalogue 067 Low-voltage Brief Catalogue

Low Voltage Brief Catalogue Low-voltage Brief Catalogue Contactor, Overload Relay

P -

NCK3 DP Contactor

CJ19 Capacitor Switching Contactor CJ19 Capacitor Switching Contactor

NCK3 DP Contactor

• The CJ19 Series Contactor is used in remote capacitor (130kvar) switch application. • Rating up to 400V, 130A (AC-6b). ----- (25A, 32A, 43A, 63A, 95A,115A,150A,170A) • Standard: IEC/EN 60947-4-1 • Ambient temp: -5 ℃ ~+40 ℃ • Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V CJ19-25: Rating current 17A (AC-6b/380V); Power of controlled capacitor≤12.5kvar. CJ19-32: Rating current 23A (AC-6b/380V); Power of controlled capacitor≤20kvar. CJ19-43: Rating current 29A (AC-6b/380V); Power of controlled capacitor≤25kvar. CJ19-63: Rating current 43A (AC-6b/380V); Power of controlled capacitor≤33.3kvar. CJ19-95: Rating current 72.2A (AC-6b/400V); Power of controlled capacitor≤50kvar. CJ19-115: Rating current 87A (AC-6b/400V); Power of controlled capacitor≤60kvar. CJ19-150: Rating current 115A (AC-6b/400V); Power of controlled capacitor≤80kvar. CJ19-170: Rating current 130A (AC-6b/400V); Power of controlled capacitor≤90kvar. � Standard: IEC/EN 60947-4-1 � Ambient temp: -5℃~+40℃ � Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V CJ19-25: Rating current 17A (AC-6b/380V); Power of controlled capacitor � 12.5kvar. CJ19-32: Rating current 23A (AC-6b/380V); Power of controlled capacitor � 20kvar. CJ19-43: Rating current 29A (AC-6b/380V); Power of controlled capacitor � 25kvar. CJ19-63: Rating current 43A (AC-6b/380V); Power of controlled capacitor � 33.3kvar. CJ19-95: Rating current 72.2A (AC-6b/400V); Power of controlled capacitor � 50kvar. CJ19-115: Rating current 87A (AC-6b/400V); Power of controlled capacitor � 60kvar. CJ19-150: Rating current 115A (AC-6b/400V); Power of controlled capacitor � 80kvar. CJ19-170: Rating current 130A (AC-6b/400V); Power of controlled capacitor � 90kvar. � The CJ19 Series Contactor is used in remote capacitor (130kvar) switch application. � Rating up to 400V, 130A (AC-6b). ----- (25A, 32A, 43A, 63A, 95A,115A,150A,170A)

• The NCK3 Series DP Contactor is used in remote motor of air-conditioner (<60HP) control application. • Rating up to 630V, 90A. ----- (25A, 30A, 32A, 40A, 50A, 60A, 75A, 90A) • Standard: Ul508 � The NCK3 Series DP Contactor is used in remote motor of air-conditioner (<60HP) control application. � Rating up to 630V, 90A. ----- (25A, 30A, 32A, 40A, 50A, 60A, 75A, 90A) � Standard: Ul508 • Poles: 1P+1NC, 1P+N, 2P, 3P • Ambient temp: -5 ℃ ~+40 ℃ • Coil voltage (AC): 24V, 110V, 120V, 220V, 240V (50/60Hz). � Poles: 1P+1NC, 1P+N, 2P, 3P � Ambient temp: -5℃~+40℃ � Coil voltage (AC): 24V, 110V,120V, 220V,240V (50/60Hz).

NCK3

CJ19

CJ19

NCK5 DP Contactor

NCK5 DP Contactor ▪ The NCK5 series DP contactor is used for remote motor control of air-conditioner. ▪ Rating up to 600V, 40A (20A, 25A, 30A, 32A, 40A). ▪ Standard: UL/CSA 60947-4-1 ▪ Poles: 3P, 4P ▪ Ambient temp.: -5℃~+40℃ ▪ Coil voltage (AC): 24V, 36V, 48V, 110V, 120V, 220V, 208~240V, 277V, 440V, 480V (50/60Hz) ▪ Different wiring terminals for selection. • The NCK5 series DP contactor is used for remote motor control of air-conditioner. • Rating up to 600V, 40A (20A, 25A, 30A, 32A, 40A). • Standard: UL/CSA 60947-4-1 • Poles: 3P, 4P • Ambient temp.: -5 ℃ ~+40 ℃ • Coil voltage (AC): 24V, 36V, 48V, 110V, 120V, 220V, 208~240V, 277V, 440V, 480V (50/60Hz) • Different wiring terminals for selection. ▪ Standard: IEC 60947-4-1 ▪ Rating current: 65A ▪ With 4NC main contacts, suitable for long-time closed applications, such as pre-pay meters. ▪ Compact design, 10% smaller than NC1-65 with same install dimension. ▪ Modular design without auxiliary contact, and can combine NCF-11C auxiliary contact module on both sides. ▪ Suitable for screw installation and DIN rail installation.

NCK5

NR8 Thermal Overload Relay NR8 Thermal Overload Relay

NC11 AC Contactor

NCK5

• NR8 series thermal overload relay is used to provide overload and phase failure protection for AC motors • Frequency: AC 50Hz/60Hz ▪ NR8 series thermal overload relay is used to provide overload and phase failure protection for AC motors ▪ Frequency: AC 50Hz/60Hz

• Voltage: up to 690V • Current: 0.1A~38A • Standard: IEC 60947-4-1. ▪ Voltage: up to 690V ▪ current: 0.1A~38A ▪ Standard: IEC 60947-4-1.

NRB

NC11

NR8

NCH8 Modular AC Contactor NCH8 Modular AC Contactor

NRE8 Electronic Overload Relay NRE8 Electronic Overload Relay

• For controlling the household device or similar low inductive electric device • Manufactured according to IEC/EN 61095 • Utilization category: AC-1, AC-7a, AC-7b • Electric ratings: up to 20A, 25A, 40A, 63A, 230V, 400V, AC50/60Hz • Various contact assembly are available � For controlling the household device or similar low inductive electric device � Manufactured according to IEC/EN 61095 � Utilization category: AC-1, AC-7a, AC-7b � Electric ratings: up to 20A, 25A, 40A, 63A, 230V, 400V, AC50/60Hz � Various contact assembly are available

• The NRE8 Series Electronic Overload Relay is used in remote motor control application for overload function. • Rating up to 690V, 630A (AC-3). ----- (25A, 40A, 100A, 200A, 630A) � The NRE8 Series Electronic Overload Relay is used in remote motor control application for overload function. � Rating up to 690V, 630A (AC-3). ----- (25A, 40A, 100A, 200A, 630A) � Standard: IEC/EN 60947-4-1 � Ambient temp: -5℃~+40℃ � Assemble with Contactor NC1, NC2, NC7,NC8 to be a DOL Starter. • Standard: IEC/EN 60947-4-1 • Ambient temp: -5 ℃ ~+40 ℃ • Assemble with Contactor NC1, NC2, NC7,NC8 to be a DOL Starter.

NCH8 NCH8

NRE8

NRE8

Powered by